Electric motors

General purpose industrial electric motors are manufactured in the standard version:
— mounting type IM 1001 (IMB3);
— climatic category У3;
— S1 duty cycle.
All electric motors are of EFF2 level according to European Energy Regulations.
In order to protect electric motors from over-heating in case of emergency operation, stator windings include thermal switches (one for each phase) connected in series. The contacts of thermal switches are connected to special terminals in the terminal box. Relays and other external protecting devices are connected to these terminals. Thermal switch ensures reliable and accurate protection in case of overheating, overload, phase loss, etc. According to IEC/EN 60034-11 requirements, protection response temperature for electric motors with F insulation class should be 140 C°. Electric motors with IP55 protection class are made in enclosed ventilated body that guarantees fail-safe operation.

Rotary generators

For the most effective heat recovery and reduce heat consumption, it is advisable to use rotary regenerator units.
Through the use of cuttings through heat of exhaust air, the efficiency of talotibial reaches 80%.

Heat Exchangers

The ventilation system of the building - one of the most important engineering life support systems. Reduced energy consumption in the preparation of the air is an important component in a complex of measures for energy efficiency of the building as a whole.
The most effective way to reduce energy consumption in the operation of ventilation systems rightfully heat recovery technology of the secondary flow, ie, Exhaust air heat is very energy-intensive secondary flow. The highest efficiency among these devices has a rotary regenerator.

FT fan motors

FT fan motors with forward curved blades are used for rectangular fans manufacturing. Three-phase fans operate using 3 ~ 400V (Υ) и 3 ~ 230V (Δ) voltage. All fans are equipped with Klixon type thermal contacts (bimetallic strip that breaks the circuit in case of overheating). Three-phase fans have two thermal contacts connected in series. hree-phase fans can be controlled by voltage transformer type regulators (control steps: 95V-145V-190V-240V-400V), phase regulators and frequency controllers (control range: 1 – 50Hz). One-phase fans are controlled by voltage transformer type regulators (control steps: 65V-110V-135V-170V-230V) and phase regulators.

Compressors

The compressor-condenser units serve as sources of cold for Central air conditioners or channel supply units equipped with a section of freon air cooling(also called a direct evaporation section). This method of cooling the supply air requires less installation costs than chilling with chiller and water cooling section, but smooth control of the cooled air temperature is not possible: KKB can be either turned on or off (for powerful KKB, step-by-step adjustment of the cooling capacity is possible).

Fancoil

Fancoil characterized by high performance and maximum noise. Modern the design allows you to combine units with any type of room. They provide air conditioning with optimal air distribution, thanks to a special fan and adjustable deflectors. The dimensions of the outer panel meet European standards for suspended ceilings. Wide range models and a large selection of accessories make fan coil units that meet any customer requirements.